Includes PTU-2 and PTU-4 models.
|
PROBLEM |
POSSIBLE CAUSE |
CHECK THIS |
|
Tilt platform will not raise |
Battery may need charging |
Battery volt level |
|
|
|
Is the charger putting out 12 volts? |
|
|
|
Check that 12 volts is being reached at the motor and motor relay. |
|
|
|
Is the charger operating properly? |
|
|
Load is too heavy |
Verify the load weight. |
|
|
Unit is low on oil |
Inside the tank, make sure the oil is full to the elbow in the filler pipe. |
|
|
Tank vent may be plugged |
Look to see that the solid plug is not in place of the vent plug. |
|
|
Suction filter may be clogged |
Remove and clean the suction filter. |
|
|
Down valve coil may be energized |
Remove the down valve and ensure it is not being energized when the up button is pushed. Check wiring to the down valve. |
|
Unit elevates but will not hold a load |
Down valve coil may be energized |
Remove the down valve and ensure it is not being energized when the up button is pushed. Check wiring to the down valve. |
|
|
|
Ensure debris is not holding the down valve plunger open. |
|
|
Cylinder may be leaking |
Look at the vent line for signs of oil. |
|
Unit fails to lower |
Down valve coil may not be energized |
Make sure the coil is energized when the down button is pushed. |
|
|
|
Ensure the down valve itself is shifting and allowing oil to go back to the tank (do not remove this under pressure). |
|
|
|
Check that nothing is binding, causing the unit not to lower. |